1611A/VS wired thermal validation system complies with FDA regulations and GMP guidelines, and is the ideal solutions for process temperature measurements of sterilization equipment in pharmaceutical, food and other industries.
ZHICE-ELEC provides a complete set of self-owned brand solutions from validator and temperature field to validation probes and software. The 161XA/VS wired thermal validation system is comprised of the validator, which has a built-in battery and can be used as a stand-alone unit or be connected to a PC via LAN/USB. Input channels are expandable by connecting the validator/acquisition units with RS485. The system equips with FDA 21 CFR Part 11 compliant validation software that enables intuitive setups, graphing, reporting and backups.
Product Features
Compact design, hand-held validator, easy to carry
0.1℃ accuracy, 0.01℃ resolution
Universal input 68 or 24 channels, real-time data display
Sampling rate 100 channels per second,10ms high-speed measurement
RS485 input channel, multiple cascades, easy to expand channels
Powered by adapter or lithium battery, suitable for various test scenes
Data files stored in internal memory or USB
Channel setups can be done on APP
Validation software automatically calculates F0, FH, and A0 values
Three-level user management authority, meet requirements
Electronic signature settings, audit trails
Stand-alone operation, multi-device validation, offline validation and other flexible applications
Name | Model | Specification |
Validator |
ZCDAQ 1611A/68 |
68-channel thermocouple signal input, with options for fast, medium, and slow scanning, 6.5-digit display resolution, 3.5-inch LCD screen. 8GB internal memory and external USB drive, powered by DC 8.4V adapter or lithium battery, size 195mm*149mm*53mm (L*W*H).
|
ZCDAQ 1612A/24 |
24 channel thermocouple and other general multi-signal differential isolation input, 2 channels (optional 24V loop power supply) current measurement channels, 2 chnannels DC5V, 2 channels DC24V DC power supply for transmitter,fast, medium and slow scanning options, 6.5-bit display resolution, 3.5-inch LCD screen display, 4M memory, Extemal U disk,powered by DC12.6V adapteror lithium battery, DC12.6V/4500mAh lithium battery, standby time about 20h, size 202mm*141mm*81mm (L*W*H).
|
|
Validation Software |
MET TEMP-VS |
21CFR-11 compliance for electronic signatures,audittrails,secure authentication,and data storage |
Moist heat validation probe |
PT-SW(TC-T-24-PFA) |
T-type thermocouple, Class 1, PFA outer skin waterproof design, 260℃ temperature resistance, TFE top, single wire |
PT-SW/S(TC-T-24S-PFA) |
T-type thermocouple, Class 1, PFA outer skin waterproof design, 260℃ temperature resistance, TFE top, seven-wire
|
|
Dry heat validation prob |
Pk-OW(TC-K-24-SB) |
K-type thermocouple, Class 1,Stainless steel braided outer protection design, 482℃ temperature resistance, stainless steel sleeve head, single wire
|
Pk-OW/S(TC-K-24S-KAP) |
K-type thermocouple,class 1,Kapton outer protection design, 400℃ temperature resistance, stainless steel sleeve head, single wire
|
|
Ultra high temperature probe |
TC-K-24-INC |
K-type thermocouple, class 1, Alloy braided outer protective layer design, temperature resistance 1080℃, single wire |
UItrafine probe |
PT-FW(TC-T-30-PFA) |
T-type thermocouple, class 1, PFA outer protective layer, temperature resistance 150℃, single wire |
Temperature & humidity probe |
HT85-S |
Range:-40-105℃,0-100%RH, Accuracy:≤±0.3℃(5-60℃),≤±2.0%RH (0~90%RH@25°C) |
HC2A-S |
Range:-50-100℃,0-100%RH,Accuracy:≤±0.1℃(10~30°C),≤±0.8%RH(10~30°C)Calibration point:10,36,80%RH@23℃ |
|
Pressure sensor | WP435B |
Range:-0.1 to 0.4Mpa, Accuracy: Class 0.5, Working Voltage: 24VDC, Output Signal:1~5VDC |
Temperature field | ZCDW |
ZCDW-350H-P ZCDW-660H-P ZCDW-40L-P ZCDW-90L-P Dry well series temperature range:-90-660℃ |
ZCTB |
ZCTB-300DH、ZCTB-20DL、ZCTB-40DL、ZCTB-80L.Calibration bath series, temeprature range:-80-300℃ |
|
Temperature
reference probe |
AR22-TFL4-1/10B |
for 3-point calibration reference. Range: -50-250℃ Accuracy:±0.05℃, 1/10 Class B. Characteristic parameter: 0.00385 |
PR5627A |
for 3-point calibration reference. Range: -200 to 400℃ Accuracy: ±0.026℃@-196℃, ±0.046℃@0℃,±0.077℃@200℃,±0.124℃@420℃, Characteristic parameter: 0.00385. Nominal resistance: 100Ω ± 1Ω
|
|
5609 |
for 3-point calibration reference. Range: -200 to 670℃ Accuracy: ±0.05℃。±0.007℃@-200℃,±0.008℃@0℃,±0.020℃@420℃,±0.027℃@660℃ |
|
Feed thru | VS-ACCO1 | 316L stainless steel, pressure resistance 5MPa |
Tunnel oven probe holder |
VS-ACCO2 | 316L stainless steel material, 10-20 points can be arranged |
Freeze dryer isothermal bloc |
VS-ACCO3 | Copper, to fix the probe and isothermal with the plate |
Case | VS-CASE | Hard plastic protective case with tug for easy on-site protection and portability |